Tests

Test load-distribution resistance deviation

Tests v1.1.0/pss/power-electronics/outstage/load-distribution/* make use of a resistance \(R \approx 300 m \Omega\) because \(R = 100 m \Omega\) would require cutting the available wire, which is not desired.

The test result is assumed to be of the same significance.

Outstage Unit #1.1

Test ID Status Measured
v1.1.0/pss/power-electronics/outstage/load-distribution/positive pass \(U_{RE+,n} = 1.1 V\), \(U_{RE-,n} = 0.86 V\)
v1.1.0/pss/power-electronics/outstage/load-distribution/negative pass \(U_{RE+,n} = -0.9 V\), \(U_{RE-,n} = -1.1 V\)
v1.1.0/pss/power-electronics/outstage/short-circuit/positive pass \(U_{RE,n} = 1.04 V\), \(I_{Output} = 10.5 A\)
v1.1.0/pss/power-electronics/outstage/short-circuit/negative pass \(U_{RE,n} = -1.02 V\), \(I_{Output} = -10.4 A\)

Outstage Unit #1.2

Test ID Status Measured
v1.1.0/pss/power-electronics/outstage/load-distribution/positive pass \(U_{RE+,n} = 1.08 V\), \(U_{RE-,n} = 0.83 V\)
v1.1.0/pss/power-electronics/outstage/load-distribution/negative pass \(U_{RE+,n} = -1.10 V\), \(U_{RE-,n} = -0.85 V\)
v1.1.0/pss/power-electronics/outstage/short-circuit/positive pass \(U_{RE,n} = 1.2 V\), \(I_{Output} = 10.25 A\)
v1.1.0/pss/power-electronics/outstage/short-circuit/negative pass \(U_{RE,n} = -0.8 V\), \(I_{Output} = -10.18 A\)